The altitude chamber’s main use is for testing samples at different altitudes as well as being able to control the temperature. The chamber also has a humidity mode of operation where the samples to different humidity and temperature ranges. While in altitude mode if you have sensitive electronic equipment the chamber can keep greater than 20% RH while testing at or below 5,000 feet. This will allow you to safely turn on sensitive electronics and not cause static arcing or discharge.

| System Specifications | |
|---|---|
| Manufacturer | Espec |
| Type / Model | EVTH8-CWA |
| Working Envelope | 8 cubic feet: 24"x 24"x 24" (W x D x H) |
| Operating Temperature |
-40℃ to 100℃ (-40℉ to 212℉) |
| Altitude Range | Sea Level to 100,000 feet |
| Humidity Range | 20% RH to 95% RH +/- 5% (Non-Altitude Mode); Greater than 20% uncontrollable in Altitude Mode below 5,000 feet |
| Change Rates |
|
Download a copy of the system specifications.: